128
Error
On lift arms switch (B13):
On signal although tail lift is closed
-> Short-circuit on B13
With MBB Control Eco
-> B16 Lift arms switch defective
Automatic error reset as soon as
correct values are reached
Error
Lift arms tilt sensor (B15):
Faulty sensor signal
Error
Head tilt sensor (B15):
Faulty sensor signal
Error
Warnfix: short-circuit recognized
Switch control box off/on or close
tail lift
Error
Box body light/control box LED: short-
circuit recognized
Error
General short-circuit error of external
system
Switch control box off/on or de-en-
gergize PC board
Error indication (7 segments, flashing (0.5 Hz), System LED flashing red (2 Hz)
Status Description Action for error reset