ENGLISH
- 52 (E) -
3. Electronic Shutter Synchro Scan Setting
[Synchro Scan: 50.24 Hz to 15.63 kHz]
This setting is possible only when Electronic Shutter
setting (-2) is at S/Scan.
Horizontal bar noise can be reduced by synchro-
scan adjustment in shooting workstation scenes, for
example.
K For luminance settings at each shutter speed and
synchro-scan shutter speed, refer to the table
below.
4. CCD Read Out Mode Setting
[V Resolution: Normal, Fine]
Normal: Normal image. (CCD storage will be by field
storage.)
Fine: Vertical resolution increases. (Vertical resolution
is raised without increasing residual images by
frame storage and Electronic shutter.)
Normal is recommended for general use because
sensitivity will decrease at the Fine setting.
5. PC Control Access Speed Setting
[Baud Rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps]
Select a communication speed in controlling the
camera from the computer.
6. Component Output Setting
[Signal Select: RGB, Y/Pr/Pb, Y/C]
This enables RGB, Y/Pr/Pb or Y/C to be selected as
the component signals which are to be output from
the I/F REMOTE connector.
7. Digital Extender Setting
[Digital Extender: OFF, ON]
OFF: Under normal circumstances, this setting is
used.
ON: An extender effect which is approximately
1.5 times greater is achieved.
However, the resolution drops when the digital
extender is set to “ON”.
8. Fan Setting [Fan: OFF, Auto]
(models AW-E750, AW-E655 only)
OFF: Select this setting to stop the fan when its
operating sound is found to be bothersome in a
studio or other such environment.
Auto: The temperature is detected automatically, and
the fan starts operating when the temperature
exceeds approx. 10 °C in the storage mode or
approx. 35 °C in any other mode.
Under normal circumstances, the “Auto” setting is
used.
Shutter Speed Synchro-scan Required luminance ratio
OFF 1
1/120 120.2 Hz 2
1/250 250.0 Hz 4
1/500 492.2 Hz 8
1/1 000 984.4 Hz 16
1/2 000 1.969 kHz 32
1/4 000 3.938 kHz 64
1/10 000
7.875 kHz
160