Test mode
Name Time (When test point Remarks
Short-circuited)
Sleep Mode Waiting 1 hr. 6 sec.
Sleep Mode Operation 8 hrs. 48 sec.
Real Timer
1 hr. 1 min.
10 min. 10 sec.
1 min. 1 sec.
Time Delay Safety Control 2 min. 58 sec. 0 sec.
Forced Operation 60 sec. 0 sec.
Time Save Control 7 min. 42 sec.
Anti-Freezing 4 min. 0 sec.
Mode Judgement 20 sec. 0 sec.
Soft OFF 6 min. 36 sec.
ON 10 min. 60 sec. SOFT DRY : 10 min.
operation
Deodorizing
Control
40 sec. 4 sec.
Cooling 70 sec. 7 sec.
20 sec. 2 sec.
180 sec. 18 sec.
Soft Dry 40 sec. 4 sec.
360 sec. 36 sec.
Comp. Reverse Rotation
Detection
5 min. 30 sec. Comp. ON 5 min. and above
2 min 0 sec.
Comp./ Fan Motor Delay
Timer
1.6 sec. 0 sec.
SLo Timer 8 sec. 8 sec.
Test mode
Name Time (When test point Remarks
Short-circuited)
Intake Air Anti-Freezing
Prevention
16 min. 96 sec.
POWERFUL MODE 15 min. 15 sec
Random FM Timer
(ECONOMY Mode)
5 sec. 5 sec.
Random Auto Restart
Control
0 ~ 150 sec. 0 sec.
22.1. REMOTE CONTROL
91