EasyManua.ls Logo

Panasonic CS-PC12TKF - Page 43

Panasonic CS-PC12TKF
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
12.2.2 Soft Dry Operation Time Diagram (For PC18/24TKF)
Lo- Lo- Lo- Lo- Lo- Lo- Lo- Lo- Lo- Lo- Lo-
10’
6’
60”
6’
6’4’
60” 60” 60”
3’
10ºC
2ºC
Indoor
Heat Exchanger
Temperature
Cooling ON
Cooling OFF
Soft Dry ON
Soft Dry
OFF ~ ON
Intake Air
Temperature
Setting
Temperature
1.5ºC
1.0ºC
Time Frame
Compressor
Indoor Fan (Auto Fan Speed)
Outdoor Fan
Operation LED
<Description of operation>
h - i, l - m, o - p, v - w
: Minimum 60 seconds forced operation
n - o
: Minimum 3 minutes restart control (Time Delay Safety Control) -
Cooling operation
f - h, i - k, s - u
: Minimum 6 minutes restart control (Time Delay Safety Control) -
Soft dry operation
q - v
: Freeze Prevention Control
Operation
Stop
a
b
c
d
e
f
g
h
i
j
k
lm
n
o
p
q
rs
t
u
v
w
x