14
Indoor Unit : CS-ME5PKE, CS-E9/12PB4EA, CS-E9/12GFEW, CS-E9/12GFEW-2, CS-RE9/12RKEW,
CS-E9PD3EA, CS-E12QD3EAW, CS-E7/9/12QKEW, CS-XE7/9/12QKEW, CS-MRE7RKE
Outdoor Unit : CU-2E12SBE
Indoor unit capacity
Cooling
Total
Cooling Capacity (kW) Input Power (W) EER
ANNUAL ENERGY
CONSUMPTION
(kWh)
Current,
230V (A)
MOISTURE REMOVAL
VOLUME
l/h
Room A Room B Total min ~ max Rating min ~ max W/W CLASS
1 Room
1.6 1.6 1.60 1.60 1.1 ~ 2.3 410 220 ~ 600 3.90 A 205 1.95 1.0
2.0 2.0 2.00 2.00 1.1 ~ 2.9 520 220 ~ 750 3.85 A 260 2.45 1.3
2.5 2.5 2.50 2.50 1.1 ~ 3.5 670 220 ~ 1000 3.73 A 335 3.15 1.5
2.8 2.8 2.80 2.80 1.1 ~ 3.5 750 220 ~ 1000 3.73 A 375 3.50 1.6
3.2 3.2 3.20 3.20 1.1 ~ 4.0 920 220 ~ 1220 3.48 A 460 4.30 1.8
2 Room
1.6 + 1.6 3.2 1.60 1.60 3.20 1.5 ~ 4.0 750 250 ~ 1000 4.27 A 375 3.50 1.0 + 1.0
1.6 + 2.0 3.6 1.60 2.00 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 1.0 + 1.3
1.6 + 2.5 4.1 1.40 2.20 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 0.9 + 1.4
1.6 + 2.8 4.4 1.30 2.30 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 0.8 + 1.5
1.6 + 3.2 4.8 1.20 2.40 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 0.7 + 1.5
2.0 + 2.0 4.0 1.80 1.80 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 1.2 + 1.2
2.0 + 2.5 4.5 1.60 2.00 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 1.0 + 1.3
2.0 + 2.8 4.8 1.50 2.10 3.60 1.5 ~ 4.5 800 250 ~ 1100 4.50 A 400 3.75 1.0 + 1.4
2.0 + 3.2 5.2 1.40 2.20 3.60 1.5 ~ 4.5 770 250 ~ 1050 4.68 A 385 3.60 0.9 + 1.4
2.5 + 2.5 5.0 1.80 1.80 3.60 1.5 ~ 4.5 770 250 ~ 1050 4.68 A 385 3.60 1.2 + 1.2
2.5 + 2.8 5.3 1.70 1.90 3.60 1.5 ~ 4.5 770 250 ~ 1050 4.68 A 385 3.60 1.1 + 1.2
2.5 + 3.2 5.7 1.60 2.00 3.60 1.5 ~ 4.5 770 250 ~ 1050 4.68 A 385 3.60 1.0 + 1.3
2.8 + 2.8 5.6 1.80 1.80 3.60 1.5 ~ 4.5 770 250 ~ 1050 4.68 A 385 3.60 1.2 + 1.2
Indoor unit capacity
Heating
Total
Heating Capacity (kW) Input Power (W) COP
ANNUAL ENERGY
CONSUMPTION
(kWh)
Current,
230V (A)
MOISTURE REMOVAL
VOLUME
l/h
Room A Room B Total min ~ max Rating min ~ max W/W CLASS
1 Room
1.6 1.6 2.60 2.60 0.7 ~ 3.8 690 170 ~ 1110 3.77 A 345 3.05
2.0 2.0 3.20 3.20 0.7 ~ 4.8 850 170 ~ 1410 3.76 A 425 3.75
2.5 2.5 3.60 3.60 0.7 ~ 5.5 1030 170 ~ 1700 3.50 B 515 4.55
2.8 2.8 4.00 4.00 0.7 ~ 5.5 1150 170 ~ 1700 3.48 B 575 5.10
3.2 3.2 4.40 4.40 0.7 ~ 5.6 1220 170 ~ 1680 3.61 A 610 5.40
2 Room
1.6 + 1.6 3.2 2.20 2.20 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
1.6 + 2.0 3.6 1.95 2.45 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
1.6 + 2.5 4.1 1.70 2.70 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
1.6 + 2.8 4.4 1.60 2.80 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
1.6 + 3.2 4.8 1.45 2.95 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
2.0 + 2.0 4.0 2.20 2.20 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
2.0 + 2.5 4.5 1.95 2.45 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
2.0 + 2.8 4.8 1.85 2.55 4.40 1.1 ~ 5.6 950 210 ~ 1270 4.63 A 475 4.20
2.0 + 3.2 5.2 1.70 2.70 4.40 1.1 ~ 5.6 920 210 ~ 1220 4.78 A 460 4.10
2.5 + 2.5 5.0 2.20 2.20 4.40 1.1 ~ 5.6 920 210 ~ 1220 4.78 A 460 4.10
2.5 + 2.8 5.3 2.10 2.30 4.40 1.1 ~ 5.6 920 210 ~ 1220 4.78 A 460 4.10
2.5 + 3.2 5.7 1.95 2.45 4.40 1.1 ~ 5.6 920 210 ~ 1220 4.78 A 460 4.10
2.8 + 2.8 5.6 2.20 2.20 4.40 1.1 ~ 5.6 920 210 ~ 1220 4.78 A 460 4.10