1.4 Specifications
32 Installation Manual
Power Supply Unit Selection
Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the load
figure from the type and number of items of equipment to be connected, and determine the type of PSU that
will be required.
Load Figure Calculation
PSU Capability
Each PSU supports a different amount of load figures.
Calculation Example (KX-TDA200)
Equipment Type Load Figure
PT KX-T7600 series DPT/DSS console 1
Other DPT/DSS console 4
APT 4
IP-PT 0
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the load figures.
DHLC8 8
SLC8 8
SLC16 16
MSLC16 16
CS (1 unit) 4
PT-interface CS (1 unit) 4
VPS (1 port) 1
PSU Type Maximum Load Figures
PSU-S
*1
*1
Available for the KX-TDA100
64
PSU-M
*2
*2
Available for the KX-TDA100 and KX-TDA200
128
PSU-L
*3
*3
Available for the KX-TDA200
512
Equipment Type Load Figure
KX-T7600 series DPT 48 units 48
Other DPT 2 units 8
SLC16 1 card 16
MSLC16 1 card 16
VPS 8 ports 8

Table of Contents