No.SX-DSV03335
Cate
Pr.
Parameter
Defaul
t
value
Cate
Pr.
Parameter
Defaul
t
value
Cate
Pr.
Parameter
Defaul
t
value
Cate
Pr.
Parameter
Defaul
t
value
Cate
Pr.
Parameter
Defaul
t
value
7
0 Display on LED
07
31 No use
-7
62 No use
-7
93
Home position return limit speed
0
1
Display time setup upon power-up
0
32 No use
-
63 No use
-
94 No use
-
2 No use
-
33 No use
-
64 No use
-
95 No use
-
3
Output setup during torque limit
0
34 No use
-
65 No use
-
96 No use
-
4 For Manufacturer use
0
35 No use
-
66 No use
-
97 No use
-
5 For Manufacturer use
0
36 No use
-
67 No use
-
98 No use
-
6 For Manufacturer use
0
37 No use
-
68 No use
-
99
Communication function expansion
settin
g
s 6
0
7 For Manufacturer use
0
38 No use
-
69 No use
-
100 For Manufacturer use
0
8 For Manufacturer use
0
39 For Manufacturer use
0
70 No use
-
101 For Manufacturer use
0
9
Correction time of latch delay 1
360
40
Station alias setup
(
for controller
)
0
71 No use
-
102 For Manufacturer use
0
10 For Manufacturer use
3
41 Station alias selection
1
72 No use
-
103 For Manufacturer use
0
11 For Manufacturer use
0
42
Maximum continuation communication
error
-30584
73 No use
-
104 For Manufacturer use
0
12 For Manufacturer use
0
43 Detection time of lost link
0
74 No use
-
105 No use
-
13 For Manufacturer use
0
44 Software Ver.
-
75 No use
-
106 No use
-
14
Main power off warning detection
time
0
45 No use
-
76 No use
-
107 No use
-
15 For Manufacturer use
0
46 No use
-
77 No use
-
108 For Manufacturer use
7
16
Torque saturation error protection
fre
q
uenc
y
0
47 No use
-
78 No use
-
109 For Manufacturer use
0
17 No use
-
48 No use
-
79 For Manufacturer use
0
110 For Manufacturer use
0
18 No use
-
49 No use
-
80 No use
- 111
No use
-
19 No use
-
50 No use
-
81 No use
- 112
No use
-
20 No use
-
51 No use
-
82 No use
- 113 Torque offset filter 0
21 No use
-
52 No use
-
83 No use
- 114
No use
-
22
Communication function
ex
p
ansion settin
g
s 1
0
53 No use
-
84 No use
- 115
No use
-
23
Communication function
ex
p
ansion settin
g
s 2
16384
54 No use
-
85 No use
- 116
No use
-
24
Communication function
ex
p
ansion settin
g
s 3
14352
55 No use
-
86 No use
- 117
No use
-
25 No use
-
56 No use
-
87
Communication function expansion
settin
g
s 5
3072 118
No use
-
26 No use
-
57 No use
-
88 No use
- 119
No use
-
27 No use
-
58 No use
-
89 No use
- 120 Absolute scale offset 1 0
28 No use
-
59 No use
-
90 No use
- 121 Absolute scale offset 2 0
29 No use
-
60 No use
-
91 No use
-
30 No use
-
61 No use
-
92
Correction time of latch delay 2
0
PARAMETER MODEL MINAS-A6B(BL/BM) series
 8/11
*1 When checking directly value of parameter-file with a text data etc., it does not show the decimal point.  Ex) Pr6.24 Load change compensation filter ・・・ Value of Panaterm 0.53 / Value of parameter-file 53
* Parameter names in the table correspond to the DD motor (rotary type). For parameter names and setting values corresponding to linear motors, refer to the technical document.

Table of Contents