No. SX-DSV03335 - 35-
R2.0 Industrial Device Solution Business Unit, Panasonic Corporation
Main power input
terminal
For single-phase, the connector should be connected to the L1 and L3 terminals.
Single-phase/three-phase 200 - 240 V
For single-phase, the connector should be connected to the L1 and L3 terminals.
Control power input
terminal
• Do not connect anything to this connector.
Regenerative resistor
connecting terminal
To use an external regenerative resistor (customer prepared), connect an external
regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Refarence - Functional Specification-"
Do not connect anything to the N terminal.
Connect each phase of the motor wiring.
U: U phase, V: V phase, W: W phase
Earth terminal for grounding
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.