No. SX-DSV03335 - 46-
R2.0 Industrial Device Solution Business Unit, Panasonic Corporation
7-7 CS signal connector X6
CS signal power supply output
CS signal power supply output (Note1)
CS signal power output ground (Note 2)
Do not connect anything to this connector.
Internally connected to the earth terminal.
Note 1) The E5V of the is connected with the terminal No. 1 of the connector X5 (EX5V).
The power supply that can be supplied from E5V and EX5V of X5 is 5 V ± 5% 300 mA MAX.
Note 2) The E0V of the CS signal power output ground is connected with the terminal No. 2 of the connector X5
(EX0V) and control circuit ground of the connector X4 .
7-8 Analog monitor connector X7
Input / output
signal interface
• Analog signal output for monitoring.
• The meaning of the output signal varies depending on the
parameter setting.
• Do not connect anything to this connector.