3. Connect the service kit (extension cables).
·
Each flexible cable of LCD Panels (R/G/B) - Connectors (A1/A2/A3) on A-P.C.Board
·
Thermosensor (Intake air) connector - Connector (A7) on A-P.C.Board
·
Intake fan connector - Connector (A15) on A-P.C.Board
·
Power fan connector - Connector (A16) on A-P.C.Board
·
Lamp fan connector - Connector (A18) on A-P.C.Board
4. Covering with an insulator (cloth or the like) to prevent a short circuit, set the A-P.C.Board block on the main unit.
Note:
·
Handle with care not to apply external force to connecting parts which connect the main unit and A-P.C.Board.
7.5.3. Adjustment Procedure
7.5.3.1. Outline
When the lighting area is off from the adjustment and color unevenness appears, adjust the lighting area into correct position.
Symptom Measure
Magenta unevenness G Reflector Adjustment
Cyan unevenness R Reflector Adjustment
Yellow unevenness B Reflector Adjustment
·
Shifting the mirror adjusting lever horizontally, adjust color unevenness on the screen upper/lower sides.
·
Twisting the mirror adjusting lever, adjust color unevenness on the screen right/left sides.