Chapter 4 Settings — [PROJECTOR SETUP] menu
112 - ENGLISH
[COOLING CONDITION]
Change the fan control depending on the direction of projection.
Set [COOLING CONDITION] according to the projection direction, but set it to [AUTO] normally. Using the
projector with [COOLING CONDITION] set incorrectly may shorten the life of the lamp.
:
30°
30°
30°
30°
[VERTICAL UP SETTING]
[FLOOR
SETTING]
[CEILING
SETTING]
[VERTICAL DOWN SETTING]
Projection direction
1) Press as to select [COOLING CONDITION].
2) Press the <ENTER> button.
f The [COOLING CONDITION] screen is displayed.
3) Press as to select a cooling condition.
f When [AUTO] is selected, the cooling conditions of [FLOOR SETTING], [CEILING SETTING], [VERTICAL
UP SETTING], and [VERTICAL DOWN SETTING] are set automatically.
You can check the setting from [COOLING CONDITION] on the [STATUS] screen.
4) Press the <ENTER> button.
5) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
[LAMP SELECT]
Select the lamp to be turned on from the two built-in luminous lamps according to the usage conditions or
purposes.
1) Press as to select [LAMP SELECT].
2) Press qw to switch the item.
[DUAL] Two lamps will light.
[SINGLE] One lamp will light. (The lamps with shorter runtime will automatically light.)
[LAMP1] Lamp 1 will light.
[LAMP2] Lamp 2 will light.
3) Press the <ENTER> button.
Note
f For a certain time after [LAMP SELECT] is switched, [LAMP SELECT] cannot be switched again, because the lamp replacement cycle will
be shortened. Repeatedly switching [LAMP SELECT] in a short time will also shorten the lamp replacement cycle.
f The colors of the items indicate the status.
Green Current setting
Yellow Current setting (when there is a lamp that cannot turn on or failed to turn on)
Red Lamp that has failed to turn on
White Any other status
f When [SINGLE], [LAMP1], or [LAMP2] is selected, if the lamp turns off or if the runtime exceeds 4 000 hours (when [LAMP POWER] is
set to [NORMAL]), the other lamp turns on. When [DUAL] is selected, if either lamp turns off or if the runtime of either lamp exceeds 4 000
hours (when [LAMP POWER] is set to [NORMAL]), only the other lamp remains on. However, if both lamps turn off or if runtimes of both
lamps exceed 4 000 hours (when [LAMP POWER] is set to [NORMAL]), the projector turns into standby.
f Ensure that the lamp unit which is not to be turned on is also installed.
f If the setting is switched to [SINGLE], [LAMP1], or [LAMP2], both lamps turns on temporarily to prevent illuminance reduction.