EasyManua.ls Logo

Panasonic PT-RZ470 Series

Panasonic PT-RZ470 Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INF - 18
6. 3. System log data acquisition method
6. 3. 1. Equipment to be used
1. Computer : Use it for collection of log data.
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Service Software :
DataLogBackup.exe
Service software is downloaded from the projector service homepage.
6. 3. 2. Preparation
[Caution]
Set the "SERIAL" in "RS-232C INPUT SELECT"
of "PROJECTOR SETUP" menu.
6. 3. 3. Acquisition of log data
1. Switch the projector to "Normal-Standby" mode (POWER indicator is Lighting in red).
2. Start up service software
DataLogBackup.exe
with a computer.
3. Select "Option "
" Setting" and set Serial Port of the computer, Baud Rate and Parity.
4. Select a model number and ID.
1. Confirm and make a note of "Projector ID",
"Transmission speed" and ""Parity setting".
2. Correct the serial terminals on the projector and
the PC by using a communication cable.
Computer
RS-232C straight
Projector

Related product manuals