ADJ - 8
1. 6. Drive Current, White balance, Color luminance adjustment
1. 6. 1. Necessary equipments
1. Dark room : To measure the light level/color points.
2. Screens : Appros 40 inch diagonal size white mat type screen.
3. Luminqance/Color meter : recommend Konica-Minolta CL-200.
4. Serial cable from Luminance/Color meter to PC : In case using CL-200, T-A11 is the type number.
5. PC : To make communication between Luminance/Color meter to the projector.
6. Serial cable : RS-232C streight with D-sub9 male/female type for communicationg between PC to projector.
7. Service tool software : SSI_Service_Tool Please download from service web page)
1. 6. 2. Preparation
1. Set the projector lens at center position with wide end zoom.
2. Set the throw distance at 1.251.30m approx 40inch
3. Connect serial cable between projector and PC.
4. Connect Serial cable (T-A11) between Luminance/Color meterCL-200A.
1. 6. 3. Start up the equipments
1. Power on the projector.
2. Start-up the service tool software "SSI_Service_Tool" on the PC.
3. Communicate automatically, when start the SSI_Service_Tool.
"Model Info" will be displayed if it succeeds in communication.
This process shows how to adjust each light source device (LED-R, LED-B, LD, Phosphor wheel driving level.
Please follow these process when these devices are replaced.
Dark room
Serial cable (T-A11)
1.251.30m
Table
RS-232 straight
Luminance/Color meter
Screen
PJ
PC