EasyManua.ls Logo

Panasonic PT-RZ470 Series

Panasonic PT-RZ470 Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes
1. Resistor
All the resistors are carbon 1/4W resistors, unless marked as follows.
The unit of resistance is an OHM [Ω] (K=1 000 M=1 000000).
: Nonflammable : Metal Oxide
: Solid : Metal Film
: Wire Wound : Fuse
2. Capacitor
1. Block Diagram  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
DIA-2
: Temperature Compensation : Electrolytic
1.1. Power Supply and Ballast
: Polyester : Bipolar
1.2. Signal Processing
: Metalized Polyester : Dipped Tantalum
: Polypropylene : Z-Type
2. Interconnection Block Diagram  ・・・・・・・・・・・・・・・・・・・・・・・
DIA-4
3. Coil
T
he unit of inductance is a H, unless otherwise noted.
3. Schematic Diagram・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
DIA-5
4. Te
st Point
3.1. A -P.C.Board
: Test Point
3.2. G -P.C.Board 5. HOT and COLD indications
3.3. S / V / R -P.C.Board
4. Circuit Boards Diagram  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
DIA-10
6. This schematic diagram is the latest at the time of printing and the subject to change w
ithout notice.
4.1. A -P.C.Board
4.2. G / S / V / R -P.C.Board
Precautions
1. NEVER touch the HOT
part or the HOT and COLD parts at the same time, or you may get an electric shock.
2. NEVER short-circuit the HOT and COLD circuits, or the fuse may blow and the parts may break.
4. MAKE SURE to unplug the power cord from the power outlet before removing the chassis.
5. Be sure to make your orders of replacement parts according to parts list section.
3. NEVER connect an instrument such oscilloscope to the HOT
and COLD circuit simultaneously, or the fuse may blow.
Connect the ground of instruments to the ground of the circuit being measured.
CONTENTS
SECTION 4
Components identified by the international symbol have special characteristics important for safety.
When replacing any of these components, use only the manufacturer's specified ones.
The power circuit board contains a circuit area using a separate power supply to isolate the ground connection.
The circuit is defined by HOT and COLD indications in the schematic diagram. Take the precautions below:
Schematic Diagram
Model No.
PT-RZ470 Series
PT-RW430 Series
Important Safety Notice

Related product manuals