EasyManua.ls Logo

Panasonic PT-VX42Z

Panasonic PT-VX42Z
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Attaching the air lter unit
1) Attach the unused air filter unit to the projector.
f Hold the air lter unit that the tab is in up-left side in the gure, put the right side in the gure rst, and press the tab side
until make a click sound.
f Do not press any other part of the air lter unit except the frame during installation.
2) Install the air filter cover.
f Perform Step 1) in “Removing the air lter unit” (
Æ
page 116) in the reverse order.
f Make sure that the air lter cover is closed tightly.
Resetting the filter counter
Be sure to reset the lter counter after replacing the air lter unit.
1) Connect the power plug, press the <v/b> button on the control panel or the <b> button on the remote
control.
2) Press the <MENU> button to display the main menu, then press as to select [PROJECTOR SETUP].
3) Press the <ENTER> button, press as to select [FILTER COUNTER].
4) Press the <ENTER> button, press as to select [FILTER COUNTER RESET].
5) Press the <ENTER> button.
f [FILTER COUNTER RESET] conrmation is displayed.
6) Press qw to select [OK], then press the <ENTER> button.
f The lter usage time is 0 after reset.
Attention
f Turn off the power before you replace the air lter unit.
f When attaching the air lter unit, make sure that the projector is stable, and work in an environment that is safe, even in the
event of the air lter unit dropping.
f Make sure that the air lter unit is properly attached before using the projector. If it is not attached, the projector will suck in
dirt and dust causing a malfunction.
f Do not put anything into the air vents. Doing so may result in malfunction of the projector.
f The air lter unit to be replaced should be an unused product.
f After replacing the air lter, reset the lter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on
screen.
Note
f The replacement cycle of the air lter unit varies greatly depending on the usage environment.
Lamp unit
The lamp unit is a consumable component. Refer to “When to replace the lamp unit” (
Æ
page 118) for details about the
replacement cycle.
It is recommended to ask an authorized engineer to replace the lamp unit. Contact your dealer.
Consult your dealer to purchase a replacement lamp unit (ET-LAV300).
Warning
Do not replace the lamp unit when it is hot. (Wait at least 1 hour after use.)
The inside of the cover can become very hot, take care to avoid burn injuries.
Tab
ENGLISH
-
117
Chapter 5 Maintenance - Replacement

Table of Contents

Other manuals for Panasonic PT-VX42Z

Related product manuals