14.5. Self-Diagnosis Error Code Description
Code Display Abnormal Item Detection Method
F61 Abnormal output or power supply When DCDET becomes L while operating, PCONT is set to L
without usual POWER OFF processing, and F61 is displayed after
GOOD-BYE display. Occurrence of abnormality shall be
memorized and displayed in the abnormal detection display mode.
H15 OPEN SW It is memorized if there is abnormal SW while operation, and is fail-
save operation, and an abnormal content is displayed by the self-
diagnostic mode usually.
Abnormal SW is detected in the abnormal detection mode.
H16 CLOSE SW
CD F28 The DISC loading is abnormal Memory when switch is not changed even if it exceeds it to time of
fail safe time when horizontally operating toward PLAY position
doesn’t enter state of target.
When mechanism begins to operate next time, initialization is done.
Only when backup data is cleared clearly of this error No. when it
compels clearly or power supply start-up.
CD F29 The DISC unloading is abnormal
CD F27 DOWN SW is abnormal
CD F22 Mechanism is loading motor/abnormal
14.6. DVD/CD Self-Diagnosis Error Code Description
Abnormal display The error is detailed
U11 Focus servo failure
H01 Tray loading failure
H02 Spindle servo failure
H03 Traverse motor failure
H04 Tracking servo error
H05 Seek timeout failure
F010 A specified value is larger than the Parental value of a specified country.
F020 There is no TT_SRPT. (RLBN is 0.)
F021 The number of TT_SRP is 0.
F022 A specified value is larger than the number of TT_SRP.
F023 There is no SRP corresponding to VTSN or VTS_TTN.
F024 A specified value is larger than TT_SRP.PTT_Ns.
F030 The number of TTU_SRP is 0.
F031 A specified value is larger than the number of TTU_SRP.
F040 SRP1 or more is 0.
F041 The number of PGCI_SRP is 0.
F042 A specified value is larger than the number of PGCI_SRP.
F043 There is no PGCI_SRP corresponding to Menu ID.
F050 The number of TMAP_SRP is 0.
F051 A specified value is larger than the number of TMAP_SRP.
F052 Specification TMAP_SA is 0.
F053 The number of MAP_EN is 0.
F060 There is no PGMAP in PGC though C_POSIT exists.
F061 The number of PG in PGC is 0 though C_POSIT exists.
F062 A specified value is larger than the number of PG in PGC.
F063 There is no C_PBIT in PGC though C_POSIT exists.
F064 The number of PG in PGC is 0 though C_POSIT exists.
F065 Specification Cell number is 0.
F066 A specified value is larger than the number of Cell in PGC.
F067 It should be a block cell.
F070 It is not NV_PCK data.
F080 There is no Cell number under the retrieval.
F0E0 The PGC control file for the guide of the user ..DFD.. cannot be eliminated.
F0E1 There is no DFD interchangeable type with DFD main microcomputer. It is not possible to download it.
F0E2 DFD starting download PGC reproduction error
F0E3 DFD download completion waiting PGC reproduction error
F0E4 AVDEC when DFD is downloaded
F0E5 Farm file lead error when DFD is downloaded
F0E6 Falsification check error of firmware that reads DFD
F0F0 There is no farm file and it downloads it DFD unnecessary.
F0F1 There is no firmware corresponding to the DFD download condition and it is unnecessary.
F103 Illegal Highlight Position
F4FF There was no ACK though the compulsion initialization demand was done to Panecon.
F500 DSC Error
F501 DSC Not Ready Error
F502 DSC Time Out Error
F503 DSC Communication Failure
F504 The DSC data slice offset adjustment is abnormal.
F505 DSC Attention Error