EasyManua.ls Logo

Panasonic SA-PM91DEE - Changer Reliability Test 3

Panasonic SA-PM91DEE
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ageing process:
Operation
Tray 1 CLOSE
READ
OPEN
CLOSE
CHANGE
Tray 2 CLOSE
READ
OPEN
CLOSE
CHANGE
Tray 3 CLOSE
READ
OPEN
CLOSE
CHANGE
Tray 4 CLOSE
READ
OPEN
CLOSE
CHANGE
Tray 5 CLOSE
READ
OPEN
CLOSE
CHANGE
(Back to tray 1 and repeat)
Note: To exit ageing mode, press [POWER] button. The unit will power down. Do not unplug the power cord until FL display shows
“GOOD-BYE”. This is to avoid tray jam problem.
14.15. Changer Reliability Test 3
1. Enter into test mode. (Refer to section 14.1.4)
2. Press [3] button on the remote control. it enters into ageing mode.
·
During this series of operation, the number of its operation shall be shown in the alphanumeric display repeatedly.
It shall start from [ _ _ 00001]
·
It shall move up one counter when step 1~8 of the above operations end.
It shall display [ _ _ 00000] after [ _ _ 99999] has been reached.
·
Press POWER key, tray return to PLAY position and then POWER is OFF.
During test mode, if mecha operation encounters abnormality or time over , retry operation shall be done but aging test mode shall
stop.
Ageing process:
Operation
Tray 1 OPEN
CLOSE
READ
CHANGE
Tray 2 OPEN
CLOSE
READ
CHANGE
Tray 3 OPEN
CLOSE
READ
CHANGE
Tray 4 OPEN
CLOSE
READ
CHANGE
Tray 5 OPEN
CLOSE
READ
CHANGE
DISC CHECK
(Back to tray 1 and repeat)
Note: To exit ageing mode, press [POWER] button. The unit will power down. Do not unplug the power cord until FL display shows
“GOOD-BYE”. This is to avoid tray jam problem.
64
SA-PM91DEE

Table of Contents

Related product manuals