Control Box (VL-V700)
Power source Power supply unit (VL-PS240: 220 – 240 V AC, 0.2 A, 50 / 60 Hz)
24 V DC, 0.2 A
Power consumption Standby: Approx. 3.5 W
Operating: Approx. 3.7 W
Dimensions (mm)
(height ´ width ´ depth)
Approx. 210 ´ 108.5 ´ 52.5 (excluding protruding sections)
Mass (weight) Approx. 400 g
Operating environment Ambient temperature: approx. -10 °C to +50°C
Ambient temperature for power supply unit: approx. 0
°C to +50°C
Relative humidity: up to 90% (non-condensing)
Indoor installation only
Installation method Wall mount or attach to DIN rail
External material ABS (flame retardant ABS resin)
Log Text log
Save
the text logs in the external SD memory card more than 90000 items (date,
caller, receiver, operation, status)
Image log
Save the image logs in the external SD memory card up to 90000 images (over
write save) (visitors call)
Supported functions R USB 2.0 connection (to computer)
Supported operating systems: Microsoft
® Windows® 7, Windows 8,
Windows 8.1, Windows 10
R Date and time setting (HH:MM DD/MM/YYYY)
R Download/upload the name of residents, room number, and monitor setting
R Output the system configuration data
R Estimate the status of equipment in the system
R Operation setting (Terminal, terminal and camera name, pass code, and so
on)
R Supported language: English (for administrators)
R Video output up to 1 (NTSC)
R RJ-11 PBX terminal function (connected to PBX system to guard station)
Connectivity To lobby stations
Number of connectable stations: 3
Wire: 1 pair PE insulation, thickness of one conductor is from 0.65
– 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)
To distribution box
Number of connectable stations: 4 directly
(including the repeaters)
Wire: 2 pair PE insulation, thickness of one conductor is from 0.65 – 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)
To lift controller
Number of connectable stations: 3 directly
Wire: 1 pair PE insulation, thickness of one conductor is from 0.65
– 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)
To monitor
Number of connectable stations: 1
(NTSC)
Distance: based on camera specification
To PBX
RJ-11 jack
Distance: comply with the PBX specification
16