EasyManua.ls Logo

Panasonic VL-V900 - Page 22

Panasonic VL-V900
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation position of the lobby station and camera range
Views when the camera is facing forwards at 0
°. Example: Installation height is 1500 mm.
R The measurements and angles shown here are for reference purposes and may vary depending on the
environment.
Side view
Approx. 2300 mm
Image range
Approx. 115°
Approx. 500 mm
Approx.
Approx.
Approx. 1500 mm
Centre of
the Camera
lens
1600 mm
700 mm
Top view
(view when looking from above)
Approx. 500 mm
Approx. 170°
Note:
R Install the lobby station so that the lobby station is not exposed to strong light. If strong light shines on the lobby
station, the visitor’s face may not be distinguishable.
Installation
1. Open a hole in the wall for the flush mount box.
R Note the drilling dimensions of the wall surface of the flush mount box.
Front view
353 mm
159 mm
Side view
80 mm
22
4. Installation

Other manuals for Panasonic VL-V900

Related product manuals