Parameter Description and available settings Default
DOOR KEY OPEN CODE
Determines the door open code. If disabled, the door
cannot be opened using a code.
(4 digits, or #### to disable)
####
(DISABLE)
DOOR KEY EXTERNAL IN
Tells the system whether an access controller (door
opener, key switch, card reader, etc.) is connected to
the lobby station and used to unlock the door.
[00]: NO
[01]: YES
00
(NO)
DOOR KEY IN SIGNAL
Determines whether the signal received from the
access controller is a closed signal
(i.e., the signal is
normally open) or an open signal (i.e., the signal is
normally closed).
[00]: CLOSE
[01]: OPEN
R Available only when “DOOR KEY EXTERNAL IN”
is set to “YES”.
00
(CLOSE)
SET CAMERA
CAMERA CONNECTION
Tells the system whether a camera is connected or not.
[00]: NO
[01]: YES
00
(NO)
CAMERA NAME
Determines the camera name.
[01]: CAMERA #
[02]: RECEPTION
[03]: GATE
[04]: CONTROL ROOM
[05]: RESTAURANT
[06]: HALL
[07]: POOL
[08]: SECURITY OFFICE
[09]: ENTRANCE
[10]: GYM
[11]: GUEST ROOM
[12]: KID’S ROOM
[13]: PARKING
[14]: TERRACE
[15]: LIFT LOBBY
01
(CAMERA #)
DISPLAY PRIORITY
Determines which camera image is displayed when
monitoring begins.
[00]: LOBBY
[01]: CAMERA
[02]: CAMERA ONLY
00
(LOBBY)
SWITCHING IMAGE
Determines whether visitors (lobby station users) can
switch between the lobby station camera and the
external camera.
[00]: NO
[01]: YES
00
(NO)
SET WIDE/ZOOM
WIDE/ZOOM SETTINGS
Determines whether camera images are displayed in
wide mode or in zoom mode when monitoring begins.
[00]: WIDE
[01]: ZOOM
00
(WIDE)