39
Time and polarities of the ALARM/CONTROL terminal and the ALARM
terminal
Terminal Active Time Remarks
Alarm input 100 ms or more L active
Alarm output The set time on the Setup menu L active
Network error output Until the network error is cleared, or until the ERR button on
the operation window is clicked.
L active
Alarm reset input 100 ms or more L active
Emergency recording input 100 ms or more L active
Available disk capacity warning output Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
HDD error output Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
Camera error output Duration set for "Error output duration"* starting from the time
of the error occurrence, or until the camera is reset (from the
time of the error occurrence).
L active
Error output Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
Time adjustment I/O Input: 100 ms or more
Output: 1 s
Input/Output: L active
Alarm suspension input 100 ms or more L active, judged by level
External recording mode changeover 100 ms or more L active
Outage detection input 5 s or more L active
Outage processing end output 10 s or more H active
* "Error output duration" can be set on the "Basic" page of the setup menu. (Refer to the setup instructions (PDF).)
Note:
• During"Lactive(Lowactive)",thelogicwillbeimplementedwhenthevoltagelevelofsignalislow.
• During"Hactive(Highactive)",thelogicwillbeimplementedwhenthevoltagelevelofsignalishigh.