RS485 setup
The following procedure is to configure the RS485
setup when using the system controller to control the
camera(pan,tilt,etc.)viathecamera'sdataport.
1. Display theadvancedsetupmenu (page8), move
thecursortoCOMMUNICATION
, and then press
theCAM(SET)button.
This will display the RS485 setup menu.
2. Checktheunitnumber.(InstallationGuide)
The UNIT NUMBER item shows the unit number
specified by DIP Switch 1.
The factory default unit number is 1.
If DIP Switch 1 specifies 1 to 96 as the unit number,
movethecursortoUNITNUMBERandthentiltthe
joystickleftorrighttoselectaunitnumber(1to96).
Note:
•ItisnotnecessarytoconfiguretheRS485SETUP
menu SUB ADDRESS setting.
•Turn on the power and use DIP Switch 1 to
configure RS485 communication parameters.
When PELCO D is set using DIP SW, ----P is
displayed for SUB ADDRESS. In addition, to set
the PELCO D Unit Number to 32-254 using DIP
SW, tilt the joystick left or right to change Unit
Numberfromthemenu.
3. Move the cursor to BAUD RATE, and then tilt the
joystick left or right to select a baud rate setting.
Tilting the joystick cycles through the baud rate
(transmission speed) display in the sequence
shownbelow.(unit:bits/s)
The factory default setting is 19200.
4. Move the cursor to DATA BIT, and then tilt the
joystickleftorrighttoselectadatabitsetting(7or
8).
The factory default setting is 8.
5. Move the cursor to PARITY CHECK, and then tilt the
joystick left or right to select a parity bit setting
(NONE,ODD,EVEN).
ThefactorydefaultsettingisNONE.
6. Move the cursor to STOP BIT, and then tilt the
joystickleftorrighttoselectastopbitsetting(1or
2).
The factory default setting is 1.
7. Move the cursor to XON/XOFF, and then tilt the
joystickleftorrighttoselectanXON/XOFFsetting.
NOT USE :DisablesXON/XOFFdataflowcontrol.
USE :EnablesXON/XOFFdataflowcontrol.
ThefactorydefaultsettingisNOTUSE.
8. Move the cursor to WAIT TIME, and then tilt the
joystick left or right to select a wait time setting.
The wait time is the time that the camera should
wait before resending data when no receive
acknowledgement (ACK) is returned after data is
sent.
Tilting the joystick cycles through the wait time
display in the sequence shown below. (unit: ms)
ThefactorydefaultsettingisOFF.
9. Move the cursor to ALARM DATA, and then tilt the
joystick left or right to select an alarm data send
mode setting.
POLLING : Sends alarm data in response to a
request by the system controller.
AUTO1 : Sends alarm data each time an alarm
signal is input.
AUTO2 : Sends alarm data at five-second intervals.
ThefactorydefaultsettingisAUTO2.
10. Move the cursor to DELAY TIME, and then tilt the
joystick left or right to select a delay time setting.
The delay time is the time the camera should wait
beforesending a receiveacknowledge(ACK).The
delay time display changes in the sequence shown
below.(unit:ms)
ThefactorydefaultsettingisOFF.
This setting can be configured only when 2-line
configuration is selected by DIP Switch 2.
(InstallationGuide)
**RS485 SETUP**
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET TOP
1
-----
19200
8
NONE
1
NOT USE
OFF
AUTO2
---
2400 4800 9600 19200
OFF 100MS 200MS 400MS 1000MS
OFF 100MS
** RS485 SETUP **
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET TOP
P1 D32
----P
19200
8
NONE
1
NOT USE
OFF
AUTO2
OFF
[RS485 SETUP] Menu
Using a joystick,
etc., set the unit
number(32to254).
(Theillustration
shows that the unit
numberissetto32.)