18 Installer’s Manual
1) In section [007], enter the first digit where each digit from 8 to
F represents an event group (0 = PGM Disabled).
2) Then enter the second digit, which can be any digit from 0 to F
depending on the first digit chosen.
3) After entering the second digit, use Feature Select Programming
to enable/disable options [1] to [8]. Select up to eight specific
events as detailed in the PGM Programming Table.
These buttons represent the hexadecimal values from A to F:
5.3 PGM DEACTIVATION EVENT
Section 008
Once the PGM Activation Event (see section 5.2 of this manual)
has occurred, the keypad's on-board PGM will return to its
[STAY] = A ([STAY] will illuminate)
[DISARM] = D ([A4] will illuminate)
[FORCE] = B ([FORCE] will illuminate)
[BYP] = E ([BYP] will illuminate)
[ARM] = C ([A1] will illuminate)
[MEM] = F ([MEM] will illuminate)