10
PROGRAMMING GUIDE
System Timers
Section # Decimal Value (000-255) Description Default Value
[200] ___/___/___ seconds (min. = 10sec.) INTELLIZONE DELAY 10sec.
[201] ___/___/___ x20 msec. INPUT SPEED 001=PANEL TERMINAL 1 600msec.
[202] ___/___/___ x20 msec. INPUT SPEED 002=PANEL TERMINAL 2 600msec.
[203] ___/___/___ x20 msec. INPUT SPEED 003=PANEL TERMINAL 3 600msec.
[204] ___/___/___ x20 msec. INPUT SPEED 004=PANEL TERMINAL 4 600msec.
[205] ___/___/___ x20 msec. INPUT SPEED 005=PANEL DOUBLER 1 600msec.
[206] ___/___/___ x20 msec. INPUT SPEED 006=PANEL DOUBLER 2 600msec.
[207] ___/___/___ x20 msec. INPUT SPEED 007=PANEL DOUBLER 3 600msec.
[208] ___/___/___ x20 msec. INPUT SPEED 008=PANEL DOUBLER 4 600msec.
[209] ___/___/___ x20 msec. INPUT SPEED 009=ZX4 TERMINAL 1 600msec.
[210] ___/___/___ x20 msec. INPUT SPEED 010=ZX4 TERMINAL 2 600msec.
[211] ___/___/___ x20 msec. INPUT SPEED 011=ZX4 TERMINAL 3 600msec.
[212] ___/___/___ x20 msec. INPUT SPEED 012=ZX4 TERMINAL 4 600msec.
[213] ___/___/___ x20 msec. INPUT SPEED 013=ZX4 DOUBLER 1 600msec.
[214] ___/___/___ x20 msec. INPUT SPEED 014=ZX4 DOUBLER 2 600msec.
[215] ___/___/___ x20 msec. INPUT SPEED 015=ZX4 DOUBLER 3 600msec.
[216] ___/___/___ x20 msec. INPUT SPEED 016=ZX4 DOUBLER 4 600msec.
[217] ___/___/___ (max. = 15) AUTO ZONE SHUTDOWN Disabled
[218] ___/___/___ (max. = 15) AUTO TROUBLE SHUTDOWN Disabled
[219] ___/___/___ seconds RECENT CLOSING DELAY Disabled
[220] ___/___/___ tries # OF INVALID CODES BEFORE LOCKOUT Disabled
[221] ___/___/___ minutes (000 = report only)KEYPAD LOCK-OUT DURATION Report Only
[222] ___/___/___ x15 minutes NO MOVEMENT TIMER PARTITION 1 Disabled
[223] ___/___/___ x15 minutes NO MOVEMENT TIMER PARTITION 2 Disabled
[224] ___/___/___ x15 minutes NO MOVEMENT TIMER PARTITION 3 Disabled
[225] ___/___/___ x15 minutes NO MOVEMENT TIMER PARTITION 4 Disabled
[226] ___/___/___ seconds EXIT DELAY PARTITION 1 60 sec.
[227] ___/___/___ seconds EXIT DELAY PARTITION 2 60 sec.
[228] ___/___/___ seconds EXIT DELAY PARTITION 3 60 sec.
[229] ___/___/___ seconds EXIT DELAY PARTITION 4 60 sec.
[230] ___/___/___ seconds ENTRY/STAY DELAY 1 30 sec.
[231] ___/___/___ seconds ENTRY/STAY DELAY 2 60 sec.
[232] ___/___/___ seconds ENTRY/STAY DELAY 3 90 sec.
[233] ___/___/___ seconds ENTRY/STAY DELAY 4 120 sec.
[234] ___/___/___ minutes BELL CUT-OFF TIMER PARTITION 1 4 min.
[235] ___/___/___ minutes BELL CUT-OFF TIMER PARTITION 2 4 min.
[236] ___/___/___ minutes BELL CUT-OFF TIMER PARTITION 3 4 min.
[237] ___/___/___ minutes BELL CUT-OFF TIMER PARTITION 4 4 min.
[238] ___/___/___ zone(s) MAX. BYPASS ENTRIES PARTITION 1 Unlimited
[239] ___/___/___ zone(s) MAX. BYPASS ENTRIES PARTITION 2 Unlimited
[240] ___/___/___ zone(s) MAX. BYPASS ENTRIES PARTITION 3 Unlimited
[241] ___/___/___ zone(s) MAX. BYPASS ENTRIES PARTITION 4 Unlimited
[242] ___/___/___ minutes RECYCLE DELAY FOR PARTITION 1 Disabled
[243] ___/___/___ minutes RECYCLE DELAY FOR PARTITION 2 Disabled
[244] ___/___/___ minutes RECYCLE DELAY FOR PARTITION 3 Disabled
[245] ___/___/___ minutes RECYCLE DELAY FOR PARTITION 4 Disabled