PROGRAMMING GUIDE
Bold = Default setting
Bold = Default setting
Bold = Default setting
SECTION [502]: PGM & Other Options
Option OFF ON
[1] PGM 1 Deactivation Type l Follows Event l Follows Timer
[2] PGM 2 Deactivation Type l Follows Event l Follows Timer
[3] PGM 3 Deactivation Type l Follows Event l Follows Timer
[4] PGM 4 Deactivation Type l Follows Event l Follows Timer
[5] PGM 5 Deactivation Type l Follows Event l Follows Timer
[6] Auto adjust panel clock for Daylight Savings l Disabled l Enabled
[7] PGM 1 = 2-wire smoke detector input (255) l Disabled l Enabled
[8] No bell cut-off during fire alarm l Disabled l Enabled
SECTION [503]: PGM & Other Options
Option OFF ON
[1] PGM 1 Timer (see section [250]) l Seconds l Minutes
[2] PGM 2 Timer (see section [251]) l Seconds l Minutes
[3] PGM 3 Timer (see section [252]) l Seconds l Minutes
[4] PGM 4 Timer (see section [253]) l Seconds l Minutes
[5] PGM 5 Timer (see section [254]) l Seconds l Minutes
[6] Battery charge current l 350mA l 700mA
[7] AC failure does not appear in Trouble Display l Disabled l Enabled
[8] Restrict arming on battery failure l Disabled l Enabled
SECTION [504]: Keypad & Other Options
Option OFF ON
[1] Multiple Actions in User Menu l Disabled l Enabled
[2] User Code length l Fixed (see option [3] below) l Flexible (1 to 6 digits)
[3] User Code length l 4-digits (if option [2] = off) l 6-digits (if option [2] = off)
[4] Power Save Mode l Disabled l Enabled
[5] Bypass not displayed while system is armed l Disabled l Enabled
[6] Future Use l N/A l N/A
[7] EOL resistor on hardwire inputs l Disabled l Enabled
[8] ATZ (Zone Doubling) l Disabled l Enabled