Keypad Menus 10-10
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
DIAGNOSTIC MENU
890CD Common Bus Drive & 890SD Standalone Drive
78.21
Range: —.xx %
The value of the direct input, after scaling and clamping.
(Refer to the SPEED LOOP function block)
78.16
Speed Control mode and Torque Control mode selection. Torque Control mode = TRUE.
(Refer to the SPEED LOOP function block)
83.05
The final actual positive torque limit as a percentage of rated motor torque.
(Refer to the TORQUE LIMIT function block)
83.06
The final actual negative torque limit as a percentage of rated motor torque.
(Refer to the TORQUE LIMIT function block)
78.07
The auxiliary motor torque as a percentage of rated motor torque as a percentage of rated motor torque.
(Refer to the SPEED LOOP function block)
78.20
The demanded motor torque as a percentage of rated motor torque.
(Refer to the SPEED LOOP function block)