B-8  Sequencing Logic 
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D 
External Control of the Drive 
Communications Command 
When sequencing is in the Remote Comms mode, the sequencing of the Drive is controlled by writing to 
the COMMS COMMAND (PREF 95.05). 
The COMMS COMMAND parameter is a 16-bit word based on standard fieldbus drive profiles. Some bits 
are not implemented in this release (see “Supported” column of the table below). 
=0 to set ramp output to zero 
=0 to set ramp input to zero 
Reset on 0 to 1 transition