10-17 Keypad Menus
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
DIAGNOSTIC MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6511 Display
6901 Display
6.01
ANALOG OUTPUT 1
Range: .xx %
(VALUE) The demanded value to output.
(Refer to the ANALOG OUTPUT function block)
7.01
ANALOG OUTPUT 2
Range: .xx %
(VALUE) The demanded value to output.
(Refer to the ANALOG OUTPUT function block)
17.01
DIGITAL OUTPUT 1
Range: FALSE / TRUE
(VALUE) The TRUE or FALSE output demand.
(Refer to the DIGITAL OUTPUT function block)
18.01
DIGITAL OUTPUT 2
Range: FALSE / TRUE
(VALUE) The TRUE or FALSE output demand.
(Refer to the DIGITAL OUTPUT function block)
19.01
DIGITAL OUTPUT 3
Range: FALSE / TRUE
(VALUE) The TRUE or FALSE output demand.
(Refer to the DIGITAL OUTPUT function block)