D-85
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
20.00 to 640.00 V
’s maximum ac input voltage (in Volts rms).
Motor’s thermal protection feature.
MAX SPEED
Set the motor’s maximum mechanical speed (in rpm)
MAX CURRENT
4096.00 A
Set the motor’s maximum rms current.
This parameter is used to limit the current demand
PERM CURRENT
4096.00 A
Set the motor’s permanent rms current.
Permanent current at low speed (in Amp rms) or nominal current.
Refer to MOTOR CURRENT % in the FEEDBACKS function block.
A value of 100% = PERM CURRENT.
PERM TORQUE
0.00 to 30000.00 Nm
Set the motor’s permanent torque.
Refer to TORQUE FEEDBACK in the FEEDBACKS function block.
A value of 100% = PERM TORQUE.
: 0 to INT MAX rpm
Set the motor’s low speed value (in rpm) below which the current must be reduced.
If this parameter is unknown, value must be set to 0 rpm.
POLES
Set the number of motor poles, e.g. for a 4
pole motor enter "4".