Programming D-90
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
MOTOR PMAC 2
SETUP::MOTOR CONTROL::MOTOR PMAC 2
Designed for PMAC Control Mode.
The MOTOR PMAC blocks (1 & 2) store all the parameters needed to run a PMAC Motor. These parameter values are entered
automatically by the DSE 890 Configuration Tool when the tool is used to select the motor type.
The parameters are used to vary the motor permanent current as a function of the speed and define the function used for the
motor protection against overcurrent.
Parameter Descriptions
MPS1
PREF: 135.01
Default: 230 V
Range:0 to 600 V
MPS2
P
REF: 135.02
Default: 400 V
Range: 0 to 600 V
MPS3
PREF: 135.03
Default: 480 V
Range: 0 to 600 V
These parameters define the waypoints on the motor’s thermal protection curve. They represent AC input voltage (in Volts rms)
.
CURRENT AT MPS1
PREF: 135.04
D
efault: 10.60 A
Range:0.00 to
4096.00 A
CURRENT AT MPS2
PREF: 135.05
Default: 10.60 A
Range:0.00 to
4096.00 A
CURRENT AT MPS3
PREF: 135.06
Default: 10.60 A
Range:0.00 to
4096.00 A
These parameters define the rms current at the speed defined below.
SPEED AT MPS1
PREF: 135.07
Default: 2300
rpm
Range:0 to 2147483647 rpm
SPEED AT MPS2
PREF: 135.08
Default: 4000
rpm
Range: 0 to 2147483647 rpm
SPEED AT MPS3
PREF: 135.09
Default: 4800
rpm
Range: 0 to 2147483647 rpm
These parameters define the speed on the
waypoint.