D-141
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
INE COUNT X4
_
Diagnostic showing the resolver position with a resolution of 65536 points per resolver division. This diagnostic is set to 0 at
power
-up and reset when RESET LINE COUNT is TRUE.
Set the ratio of Pulley Belt system between the
encoder feedback and the motor shaft ( Typically PARVEX Torque Motors ) .
Can be used either for resolver or ENDAT encoder.
Default value is 1 ( feedback mounted directly on the motor shaft )