D-179
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
The DISABLED WORD 3, ACTIVE WORD 3 and WARNINGS WORD 3 parameters use a four digit hexadecimal number to
identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Name (MMI)
First Trip Value
Mask EXT 1
User Disable
Auto-restart
MAX SPEED LOW
33
0x0001
Yes
N/A
MAINS VOLTS LOW
34
0x0002
Yes
N/A
NOT AT SPEED
35
0x0004
Yes
N/A
MAG CURRENT FAIL
36
0x0008
Yes
N/A
NEGATIVE SLIP F
37
0x0010
Yes
N/A
TR TOO LARGE
38
0x0020
Yes
N/A
TR TOO SMALL
39
0x0040
Yes
N/A
MAX RPM DATA ERR
40
0x0080
Yes
N/A
STACK TRIP
41
0x0100
N/A
N/A
LEAKGE L TIMEOUT
42
0x0200
Yes
N/A
POWER LOSS STOP
43
0x0400
N/A
N/A
MOTR TURNING ERR
44
0x0800
Yes
N/A
MOTR STALLED ERR
45
0x1000
Yes
N/A
AT TORQ LIM ERR
46
0x2000
Yes
N/A
FW ISR TIMEOUT
47
0x4000
N/A
N/A
ENCODR CAL ERROR
48
0x8000
Yes