890CS & 890CD Common Bus Units 4-40
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
The following is a list of the Set-up parameters you may need to check before starting the drive. Set only
the ones marked with "x" for the intended mode of operation.
Note Parameters whose values are "product code dependent" will have a typical value for the size of unit.
Where possible (or required), enter an application-specific value for improved performance, otherwise
use the typical value.
Note "PREF" is a parameter reference number used by the DSE 890 Configuration Tool.
136.02
CONTROL
MODE
0 : VOLTS / HZ
1 : SENSORLESS VEC
2 : CLOSED-LOOP
VEC
3 : 4-Q REGEN
4 : PMAC*
Select the operating
mode for the drive.
* If PMAC control is
required, the motor
wizard feature in the
Tool
be used to
correctly set-up the
motor and feedback
device parameters.
Failure to do so may
servo motor.
x
(0)
x
(1)
x
(2)
x
(3)
x
(4)