Technical Specifications E-4
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
890CD – Manufacturing Product Code
Example: 890CD - 23 1300 B 0 - 0 00 - 1 A 0 0 0
Family
890 Common Bus Drive 890CD
Induction Motor 230v ratings
Supply kW
Output Current
(Vector Mode)
HP
Output Current
(Servo Mode)
Notes
Frame Size
Rating Data 320v DC 23
0.55 3.0 0.75 B
1300
B
1.1 5.5 1.5 B
1550 B
1.5 7.0 2.0 B 1700 B
2.2
11.0 3.0 B 2110
B
4.0
16.5 5.0 B 2165 B
5.5 24.0 7.5 C 2240 C
7.5 30.0 10 C 2300 C
Induction Motor 400v ratings Induction Motor 460v ratings
Supply kW
Output Current
(Vector Mode)
HP
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes Frame Size
560/650v DC 43
37
73 50 73 E 2730 E
45 87 60 87 E 2870 E
55 105 75 100 F 3105 F
75
145
100 130 F
3145 F
90 180 125 156 F 3156 F
90 180 150
180
F 3180 F
110 216 175
216 G 3216
G
132 250 200 250 G 3250 G
160 316 250 316 G 3316 G
180 361 300 361 G 3361 G
220
420
350 420 H 3420 H
250 480 400 480
H
3480 H
280 520 450
520
H 3520 H
315
590 500
590 J 3590 J
Induction Motor 400v ratings Induction Motor 460v ratings
Supply kW
Output Current
(Vector Mode)
HP
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes Frame Size
560/705v DC 53
0.55 2.0 0.75 2.0 B 1200 B
1.1 3.5 1.5 3.5 B 1350 B
1.5 4.5 2.0
4.5 B 1450 B
2.2
6.0 3.0 5.0 B 1600 B
4.0 10.0 5.0 8.0 B 2100 B
5.5 12.0 7.5 12.0 B 2120 B
7.5 16.0
10.0 14.0 B 2160 B
7.5 16.0 10.0 14.0 30% more peak
B
216S B
11.0 24.0 15.0
24.0
C 2240 C
15.0 30.0
20.0
30.0 C 2300 C
15.0 30.0 20.0 30.0 30% more peak C
230S
C
18.5 39.0 25.0 35.0 D 2390 D
22.0 45.0 30.0 40.0 D 2450 D
30.0 59.0 40.0 52.0 D 2590 D
Induction Motor 400v/500v ratings
Supply kW
Output Current
(Vector Mode)
HP
Output Current
(Vector Mode)
Output Current
(Servo Mode)
Notes Frame Size
560/705v DC 53
37 67 E 2730 E
45 79 E 2870 E
55 100 F 3105 F
75 125 F 3145 F
90 156 F 3156 F
Auxiliary supply Not required (frames B-E) 0
115v 1ph (Frame F-J only) 1
230v 1ph (Frame F-J only) 2
Brake Switch Not Fitted (mandatory for 890CD products) 0
Special Option None 00
Active Front End ('Y' caps removed - Frames E to J only) 07
Documented special options (01-99)
Performance Level Advanced 1
High 2
Destination English (50Hz) A
English (60Hz)
B
Option F None 0
SinCos Encoder (Endat 2.1) 1
Incr. Quadr. Encoder 3
Resolver 5
Resolver Repeater 6
Mark Registration (Endat 2.1 Encoder) - with restricted functionality 7
Line Synchronisation L
Option A Not fitted 0
CanOpen Comms N
ControlNet Comms C
DeviceNet
D
E
therNet /IP H
Modbus TCP/IP T
Profibus Comms P
Mark Registration (Endat 2.1 Encoder) with restricted functionality 7
RS485 S
EtherCAT K
Analogue Input Option (if fitted in slot A cannot be fitted in slot B) R
Encoder Option (if fitted in slot A cannot be fitted in slot B) E
Option B Not fitted 0
Firewire 1394A A
Special peer-peer protocol (may only be fitted when CanOpen or DeviceNet option is not fitted in slot A) X
Analogue Input Option (if fitted in slot B cannot be fitted in slot A) R
Encoder Option (if fitted in slot B cannot be fitted in slot A) E