4-45 890CS & 890CD Common Bus Units
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
11
B
SET-UP PARAMETERS
PREF
6511/6901
Display
Default
Brief Description
V/Hz
SV
CLV
4-Q
PMAC
80.02
AUTOTUNE
MODE
0 : ROTATING
1 : STATIONARY
2 : SPD LOOP
ROTATING
3 : SPD LOOP
STATIONARY
Set the type of
Autotune.
x
x
27.06
MAG CURRENT
product code
dependent
Rotating Autotune sets
actual value
Enter the No-Load
Amps from the motor
nameplate
x x x
27.14
STATOR RES
product code
dependent
Autotune sets actual
value
Motor per-phase stator
resistance
x x
27.15
LEAKAGE
INDUC
product code
dependent
Autotune sets actual
value
Motor per-phase stator
leakage inductance
x x
27.16
MUTUAL
INDUC
product code
dependent
Autotune sets actual
value
Motor per-phase stator
mutual (magnetising)
inductance
x x