E-21 Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Electrical Ratings: 890CD Frame C, 380-500V
Input currents listed at 560V DC and 650V DC assuming total source impedance of 800µH. Motor power, input current and
output current must not be exceeded under steady state operating conditions.
Model Number
890CD-532240C
(890CD/5/0024C)
890CD-532300C
(890CD/5/0030C)
890CD-53230SC
(890CD/5/S030C)
Nominal Supply Voltage
560Vdc
650-705Vdc
560Vdc
650-705Vdc
560Vdc
650-705Vdc
Motor Power
11kW
15Hp
15kW
20Hp
15kW
20Hp
External Continuous Power Rating
W
4000
4000
5000
5000
5000
5000
Vector Mode
Input Current
A
33
28
43
36
43
36
Output Current @ 3kHz
A
24
24
30
27
30
30
Power Loss @ 3kHz
W
190
190
250
230
250
260
Output Current @ 6kHz
A
22
22
25
24
26
25
Power Loss @ 6kHz
W
200
210
280
220
290
300
Output Overload Motoring
150% overload for 60 seconds (all vector modes) 180% for 1s (V/Hz mode)
Servo Mode
Input Current
A
27
23
36
32
43
34
Output Current @ 4kHz
A
20
20
25
22
30
28
Power Loss @ 4kHz
W
180
190
230
210
280
280
Output Current @ 8kHz
A
16
14
18
16
20
18
Power Loss @ 8kHz
W
170
170
210
220
280
290
Output Overload Motoring
200% overload for 4 seconds (PMAC mode)