Parker Hannifin
Figure 3 ACR9040 Dimensions
Electrical Specifications
All configurations of the ACR9000 and ACR9030 controllers have a universal
AC power supply, and the ACR9040 is designed to be powered by a DC
supply. The electrical requirements are listed in Table 7.
Controller Voltage Frequency Maximum
Power
ACR9000, ACR9030
2/4 Axis
120/240 VAC 50-60 Hz 40 VA
ACR9000, ACR9030
6/8 Axis
120/240 VAC 50-60 Hz 50 VA
ACR9040 24 VDC n/a 20 VA
Table 7 Controller Power Requirements
AC Power Supply Connector (ACR9000 and ACR9030)
A standard IEC-320 male connector resides on the front panel of the
controller. For its location, see Figure 4 and Figure 5.
Connector Specification—AC Power
Manufacturer...........................................Adam Tech or equivalent
(www.adam-tech.com
)
Connector Type.......................................IEC-320, 3-pin (male connector)
Manufacturer Part Number ..................... IECG3
26 ACR9000 Series Hardware Installation Guide