ETH Mounting Instructions
22 192-550002N10 ETH March 2019
Sensor mounting example: 2 end limits with machine zero
Figure 11: Grooves for sensors
Figure 12: Grooves for sensors, details
2.2.3. Setting the end limits
The steps described below can be best executed with energized drive. Therefore,
they may only be performed by trained and authorized personnel.
Do only travel at very low speed (<10 mm/s) and reduce the drive torque to a
minimum.
Ensure that there are no persons in the hazardous area.
The setting of the end limits depends on the application.
No sensor is to be mounted in the area of the central lubrication port (option).
The following activation positions at the mechanical end limits result from the
initiators recommended in the catalog.
The given positions "A" and "B” are estimated recommendations and may vary. We
therefore recommend to adjust the final sensor position during the initial start up.
Figure 13: Position of sensors at the mechanical limits
Position of initiators at the mechanical limits
ETH
Pitch A [mm] B [mm]
032
050
080
100
125