Lubricating intervals and amount of lubrican
37 192-550002N10 ETH March 2019
The given lubrication intervals apply.
3
3
3
3
M10 480 km 1.9 cm
3
M20 960 km 2.7 cm
3
M05 240 km 3.1 cm
3
3
3
3
3
Different operating conditions will shorten the lubrication intervals.
You will find information about short stroke applications in the catalogue
http://www.Parker.com/Literature/Electromechanical
Europe/Literature/190_550017_ETH_katalog.pdf,
http://www.Parker.com/Literature/Electromechanical
Europe/Literature/192_550017_ETH_Catalog.pdf. Please contact Parker for
details.
Lubricant
Do only use "Klüber NBU15" lubricating grease for standard cylinders!
For applications in food related areas, "Klübersynth UH1 64-62" grease is used (customized version).
After relubrication, a lubricating run must be performed. This ensures an even
distribution of the lubricating agent.
Please make sure that the entire length is traveled in both directions at a speed of
approx. 20 mm/s.
After this, the cylinder is ready for setup.
3.2.1. Relubrication via central lubrication port (standard)
Figure 34: Relubrication via central lubrication port (standard)
Central lubrication (standard)
Central lubrication (Option)
Make sure that all external stops are removed.
Retreat Electro Cylinder completely so that it touches the rear stop.
Move the cylinder by 0.5 mm into the internal buffer.
Ensure by means of control/controller that the internal buffer is not passed by
more than 0.5 mm!
This is the lubricating position.
Use a suitable pipe for the funnel type lubricating nipple, Type D1a4 DIN3405:
Beaked nozzle (Part No.: 180-006043).
Place the pipe orthogonally onto the lubricating nipple and press.
Use the defined amount of lubricant (see page 36).
The amount of lubricant applied can be defined by the number of pump strokes.
Pump the stated amount of grease onto a balance, while counting the pump
strokes.