EasyManua.ls Logo

Parker EY Series - Voltage and Current During Operating

Parker EY Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36Pvd3675_Gb_Ey_Septembre_2017
3.2.11. Voltage and current during operating
EY motors present an ATEX/IECEx certification and due to this certificate are subjected
to strict rules regarding their use. One of such rules is the use of a servoamplifier that
meets specific characteristics.These characteristics are valid for an ambient
temperature comprised between -20°C and 40°C. For an ambient temperature
comprised between 40°C and 60°C, a derating of performances has to be applied.
Supply voltage of combined servo
drive [Vrms]
230 V one-phase / three-
phase
400 V three-phase
Supply Direct Current voltage [Vdc]
310 ±10%
550 ±10%
Electric frequency of motor [Hz]
0 à 700
0 à 700
Permanent current in one phase I
0
[Arms]
with T° ambient=+40°C
EY310…*
EY430…*
EY630…*
EY860…*
4.7 Maxi
10.2 Maxi
14.5 Maxi
21.3 Maxi
2.5 Maxi
6.6 Maxi
10.3 Maxi
20.2 Maxi
Permanent current in one phase I
0
[Arms]
with T° ambient =+60°C
EY310…*
EY430…*
EY630…*
EY860…*
4.2 Maxi
9.3 Maxi
13.1 Maxi
16.6 Maxi
2.25 Maxi
6 Maxi
8.4 Maxi
15.9 Maxi
Maximum current in one phase [Arms]
EY310…*
EY430…*
EY630…*
EY860…*
17.6 Maxi
39 Maxi
55.2 Maxi
80.0 Maxi
9.4 Maxi
25.1 Maxi
39 Maxi
78.4 Maxi
Maximum permanent power of motor [W]
EY310…*
EY430…*
EY630…*
EY860…*
876 Maxi
1757 Maxi
3304 Maxi
5542 Maxi
876 Maxi
1628 Maxi
3142 Maxi
6011 Maxi
Attention:
EY motors must be connected in accordance with the
diagrams given in chapter §4.3.5

Table of Contents