4.3.4. Protection of connectors – Mounting recommendations
After connecting male and femal part of connector, cover the assembly of connector
with its protection.The protection is foreseen to be adjusted on the connector.
Once the assembly correctly positioned, lock the device through a dedicated fixing
screw - The tightening torque of this screw is comprised between 0.9 and 1.2 Nm.
Protections of connector shall be capable of being released or removed only with the
aid of a tool according to standard IEC/EN 60079-0.
The protections are designed
• To absorb an impact energy of 7 joules.
• to prevent any disconnection when the motor run
Caution :
Check the mechanical integrity of connector protectors
before their mounting. The
use of connector protectors is mandatory in
order to be in accordance with standard IEC/EN 60079-0.
Caution : The connector protector is a single-use
the latter, be sure to replace it with a new connector protector.
Parker part number: 345352P0001
Caution : The connector protector is a
compliance