65 – Pvd3675_Gb_Ey_Septembre_2017
4.3.5. Connection diagrams
Caution: The wiring must comply with the drive commissioning
manual and with recommended cables.
Warning : A bad setting of the electronic control of the close loop
(gain too high, incorrect filtring …) can occur an instability of the shaft
line, vibration, overheating or/and breakdown - . Please consult us
It is mandatory to connect 2 (green-yellow) ground cables between the
motor frame and machine.
• the first one is connected to the ground pin #2 of power connector,
• the other one is connected to the external motor housing
(see below).
The connecting of these two grounding devices is mandatory in order
to comply with ATEX standard IEC/EN 60079-0.
The ground cable cross-section must be the
same as the power cable
cross-section
(as option)
Supply: 24 VDC
(as option)
Supply Signals
PTC Thermistor (as a standard)
Thermoswitches (as option)
KTY Sensor (as option)
L2 MAIN SUPPLY:
L3 3∼ AC or 1∼ AC or = DC
ATEX AREA EY SERVO MOTOR
RESOLVER
Supply
3∼ PWM
main supply connection diagram