65Pvd3675_Gb_Ey_Septembre_2017
4.3.5. Connection diagrams
Caution: The wiring must comply with the drive commissioning
manual and with recommended cables.
Warning : A bad setting of the electronic control of the close loop
(gain too high, incorrect filtring …) can occur an instability of the shaft
line, vibration, overheating or/and breakdown - . Please consult us
It is mandatory to connect 2 (green-yellow) ground cables between the
motor frame and machine.
the first one is connected to the ground pin #2 of power connector,
the other one is connected to the external motor housing
(see below).
The connecting of these two grounding devices is mandatory in order
to comply with ATEX standard IEC/EN 60079-0.
The ground cable cross-section must be the
same as the power cable
cross-section
BRAKE
(as option)
Supply: 24 VDC
DC+ DC-
RESOLVER
(as option)
Supply Signals
SIN COS
PTC Thermistor (as a standard)
Thermoswitches (as option)
KTY Sensor (as option)
L1 SERVO DRIVE
L2 MAIN SUPPLY:
L3 3 AC or 1 AC or = DC
ATEX AREA EY SERVO MOTOR
RESOLVER
MOTOR
Supply
3 PWM
U V W PE
SERVO DRIVE
main supply connection diagram