Series F10
Cavitation
Pistons with the grinding rings intact
have been in a clean system. No over-
speed and good viscosity on the oil.
Pistons with worn piston ball. The ball is
polished due to contaminated oil and/
or overspeed.
Note!
High temperature (low viscosity) can be
a reason.