Cavitation
Cavitation
Cavitation marks in the cylinder barrel
bores, on the port side or on the valve
plate depends on air in the oil.
Reasons can be when inlet pressure/
flow isn’t sucient. Example when
stopping a fan drive and inertia will run
the motor.
Why cavitation?
Too high speed
Too low inlet pressure
(pump mode)
What consequence?
A metallic sound comes from the
system
Material damage as craters in the
goods which contaminate the
hydraulic system
Lift o if severe cavitation
Shaft seal leakage