Catalog HY08-4005-M3
114
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
115
www.parker.com/cylinderwww.parker.com/cylinder
Program Blocks
DWN
CHK
APP
EDIT LOC
SIZE
A
DWG. NO.
ISSUE
SCALE SHEET
BBESCH 03/21/19 Hybrid Actuator Series HAS 500
099176***00-A/1/099~00-BASE.316
RF0991760***-00A
2 OF 2
Parker Cylinder Divison-Des Plaines, IL 60016
(847) 298-2400 www.parker.com/cylinder
Positon Calibration
mx
d
x
m
d
10
10
0
Positon (in)
VAL TO I NT
INPUT
BASE
100
Has Temp Int
SCALE
OFFSET
X12-02
100
0
200 ms
AN IN 1
(SHT 1) Motor Control:Enable Heater
Temp Trip Point (F) Res Temp (F)
Trip
Temp Sensor Fault
158
Reservoir Temp.1
mx
d
x
m
d
1
100
0
MUL.3
RPM
Running
Reset Hour
Hours
Change Oil
-0.488
F
F
Hours X 0.1
(SHT 1) Motor Control:Cooling ON Value (F)
Reservoir Temp.1:Res Temp (F)
Motor Control:Res Temp Trip (SHT 1)
(SHT 1) Motor Control:Motor RPM
(SHT 1) Motor Control:RUNNING
(SHT 1) Motor Control:Reset Hours
(SHT 1) Motor Control:Position Value at 100%
Motor Control:Hours (SHT 1)
Heat Exchnager Control :Reservoir Temp
Cooling Command
Reservoir Temp
Cooler/Heater On Temp
Running
RPM
Cooling/Heating Loop Active
0
0
0
F
0
Heat Exchnager / Heater Control
Motor Control:Temp Sensor Fault (SHT 1)
Motor Control:Temp_2_Display (SHT 1)
1
HAS Control :Position Scaled (SHT 1)
Motor Control:Position Actual (SHT 1)
Motor Control:Oil Change required (SHT 1)