Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Catalog HY08-4005-M3
30
WARNING: This product can expose you to chemicals including Lead and Lead Compounds which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Input Overview
RReettrraacctt LLSS ((IInnppuutt))
When True (High) drive will ramp HAS unit to a stopped
condition in retract motion only. Ramp time value is set by
keypad entry Page 23 for details. It is recommended to
remove CMD input when this condition is seen.
PPrrooffiilleerr ((iinnppuutt))
When True (High) drive will spin at a 2nd predetermined
speed setting. This function allows for fast approach and
transitions to slow speed approach. Also useful for extend
and retract speed matching. See page 27 for more details.
RReesseerrvvooiirr LLeevveell ((iinnppuutt))
Option Reservoir Low Oil level detection input, unit must be
equipped with reservoir level switch function. Default setting
when tripped (High) will issue a Low Oil Level Warning on Key
pad. Through Keypad entry device can be set to "Trip" drive
in Fault Condition See Page 39 for more details
SSoouurrcciinngg OOuuttppuuttss
CCWW LLiimmiitt aanndd CCCCWW LLiimmiitt
HAS Units equipped with Limit Switch or with Stop On
PSI mode set. When condition is seen and motion
stopped, discrete output is set for indication of
condition.
For Stop on PSI see page 36 for details.
Faulted
If the drive trips under Fault condition, this output is
set true.
EEnnaabbllee ((IInnppuutt))
When True (High) drive will react to other discrete
inputs. When False (Low) inputs are ignored.
CCWW CCMMDD ((IInnppuutt))
When True (High) drive will spin the pump in a clockwise
function. HAS Speed is set by the V1setting on key pad
setup, see Page 22 for details.
The HAS orientation call out in the model code set the
extend and retract direction. Orientations "A" &
"H"(reservoir on Cap end) CW rotation Extend Cylinder,
"B" & "C" (Reservoir on Head end) CCW rotation
extends the cylinder. Orientation can be inverted
through keypad entry see page 21
CCCCWW CCMMDD ((iinnppuutt))
When True (High) drive will spin the pump in a
counterclockwise function. HAS Speed is set by the
V1setting on key pad setup, see Page 22 for details.
EEnndd ooff SSttrrookkee LLiimmiitt SSwwiittcchheess
If desired, end of stroke limit switches maybe used with
HAS Programmed Drives. Default setting is for
Normally Open type switches, Setting to Normally
Closed is done through Key Pad entry see page 25 for
more details
EExxtteenndd LLSS ((IInnppuutt))
When True (High) drive will ramp HAS unit to a
stopped condition in extend motion only. Ramp time
value is set by keypad entry Page 26 for details. It is
recommended to remove CMD input when this
condition is seen.
PPaarrkkeerr HHaannnniiffiinn CCoorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
27
wwwwww..ppaarrkkeerr..ccoomm/
cylinder
0011
0022
0033
0044
++2244 VV
0011
0022
0033
0044
0055
0066
0077
0088
0099
XX1144
XX1155
EENNAABBLLEE
CCWW CCMMDD
CCCCWW CCMMDD
EEXXTTEENNDD LLSS
RREETTRRAACCTT LLSS
PPRROOFFIILLEERR
RREESS LLEEVVEELL
CCWW LLIIMMIITT
CCCCWW LLIIMMIITT
LL
LL
00 VV
FFAAUULLTTEEDD
LL