RReettrraacctt  LLSS  ((IInnppuutt))
When True (High) drive will ramp HAS unit to a stopped 
condition in retract motion only.  Ramp time value is set by 
keypad entry Page 23 for details.  It is recommended to 
remove CMD input when this condition is seen. 
PPrrooffiilleerr  ((iinnppuutt))
When True (High) drive will spin at a 2nd predetermined 
speed setting.  This function allows for fast approach and 
transitions to slow speed approach.  Also useful for extend 
and retract speed matching.  See page 27 for more details. 
RReesseerrvvooiirr  LLeevveell  ((iinnppuutt))
Option Reservoir Low Oil level detection input, unit must be 
equipped with reservoir level switch function.  Default setting 
when tripped (High) will issue a Low Oil Level Warning on Key 
pad.  Through Keypad entry device can be set to "Trip" drive 
in Fault Condition See Page 39 for more details 
SSoouurrcciinngg  OOuuttppuuttss  
  CCWW  LLiimmiitt    aanndd  CCCCWW  LLiimmiitt  
HAS Units equipped with Limit Switch or with Stop On 
PSI mode set.  When condition is seen and motion 
stopped, discrete output is set for indication of 
condition. 
For Stop on PSI see page 36 for details. 
Faulted 
If the drive trips under Fault condition, this output is 
set true. 
EEnnaabbllee  ((IInnppuutt))
When True (High) drive will react to other discrete 
inputs. When False (Low) inputs are ignored.  
CCWW  CCMMDD  ((IInnppuutt))
When True (High) drive will spin the pump in a clockwise 
function.  HAS Speed is set by the V1setting on key pad 
setup, see Page 22 for details. 
The HAS orientation call out in the model code set the 
extend and retract direction.  Orientations "A" & 
"H"(reservoir on Cap end) CW rotation Extend Cylinder, 
"B" & "C" (Reservoir on Head end) CCW rotation 
extends the cylinder.  Orientation can be inverted 
through keypad entry see page 21
CCCCWW  CCMMDD  ((iinnppuutt))
When True (High) drive will spin the pump in a 
counterclockwise function.  HAS Speed is set by the 
V1setting on key pad setup, see Page 22 for details. 
EEnndd  ooff  SSttrrookkee  LLiimmiitt  SSwwiittcchheess
If desired, end of stroke limit switches maybe used with 
HAS Programmed Drives.  Default setting is for 
Normally Open type switches, Setting to Normally 
Closed is done through Key Pad entry see page 25 for 
more details 
EExxtteenndd  LLSS  ((IInnppuutt))
When True (High) drive will ramp HAS unit to a 
stopped condition in extend motion only. Ramp time 
value is set by keypad entry Page 26 for details.  It is 
recommended to remove CMD input when this 
condition is seen. 
PPaarrkkeerr  HHaannnniiffiinn  CCoorrppoorraattiioonn  
Cylinder Division
Des Plaines, Illinois
27
wwwwww..ppaarrkkeerr..ccoomm/
cylinder
0011
0022
0033
0044
++2244  VV
0011
0022
0033
0044
0055
0066
0077
0088
0099
XX1144
XX1155
EENNAABBLLEE
CCWW    CCMMDD
CCCCWW  CCMMDD
EEXXTTEENNDD  LLSS
RREETTRRAACCTT  LLSS
PPRROOFFIILLEERR
RREESS  LLEEVVEELL
CCWW  LLIIMMIITT
CCCCWW  LLIIMMIITT
LL
LL
00  VV
FFAAUULLTTEEDD
LL