VVaallvvee  MMooddee  00
EEnndd  ooff  SSttrrookkee  LLiimmiittss
HAS Motion can be stopped by simply adding end of stroke limit switches either internal or external to the cylinder.  
Multiple internal switch options are available.  See catalog HY08-1132-5NA for details.  
Default switch setting is for Normally Open (NO) switch types, motion stopped on true signal.  Switch setting can be 
changed to Normally Closed (NC) by keypad entry see page 40 for details. 
The HAS orientation call out in the model code set the extend and retract direction.  Orientations "A" & 
"H"(reservoir on Cap end) CW rotation Extend Cylinder, "B" & "C" (Reservoir on Head end) CCW rotation extends the 
cylinder.  Orientation can be inverted through keypad entry see page 30 for details.  FFoorr  pprrooppeerr  ooppeerraattiioonn  ooff  eenndd  ooff  ssttrrookkee  
lliimmiittss,,  tthhee  pprrooppeerr  OOrriieennttaattiioonn  mmuusstt  bbee  ccoonnffiigguurreedd..    
EExxtteenndd  LLiimmiitt  SSwwiittcchh  ((IInnppuutt  XX1155--0044))
When input X15-04 is transition from its normal state, (either NO, or NC) forward motion command will be ignored, and 
motion will decelerate at the time value set in R2 (Decell) Valve can be changed by keypad entry see page 36 for details.  
When activated forward Commands will be ignored.  HAS will be allowed to operate in Retract motion. 
RReettrraacctt  LLiimmiitt  SSwwiittcchh  ((IInnppuutt  XX1155--0055))
When input X15-05 is transition from its normal state, (either NO, or NC) retract motion command will be ignored, and 
motion will decelerate at the time value set in R2 (Decell) Valve can be changed by keypad entry see page 36 for details.  
When activated retract Commands will be ignored.  HAS will be allowed to operate in Extend motion.  
Traditional Hydraulic Valve Control equivalent 
PPaarrkkeerr  HHaannnniiffiinn  CCoorrppoorraattiioonn  
Cylinder Division
Des Plaines, Illinois
34
wwwwww..ppaarrkkeerr..ccoomm/
cylinder