VVaallvvee MMooddee 00
Traditional Hydraulic Valve Control equivalent
VVaallvvee MMooddee -- KKeeyyppaadd EEnnttrryy MMooddee 00
Expandable feature for use with Valve Mode "0" is the Stop on PSI macro built into the drive.
Stop on PSI is enabled through Keypad entry and available for use with Mode 0, 1 2 and 3.
MMaaccrroo DDeessccrriippttiioonn::
With proper pump displacement entry, pressure can be approximated without the need of a
pressure transducer. Theoretical pump pressure is calculated based upon the motor torque
constant, and amp draw of the motor.
Additional User keypad entry required to determine the direction, pressure setting and
duration required above setting to activate a stopping motion. See Page 40 for details
If precise pressure is required, please use pressure transducer option on the HAS model
code, with an external device controller.
PPaarrkkeerr HHaannnniiffiinn CCoorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
45
wwwwww..ppaarrkkeerr..ccoomm/
cylinder