Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
51
Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois USA
www.parker.com/cylinder
Catalog HY08-4005-M3
WARNING: This product can expose you to chemicals including Lead and Lead Compounds which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Reservoir Sensor Installation
Temp Sensor Part No:
0992480000 Mating Cable:
086620T005
IP Rating: IP67
Connector: M8 Nano 3 pin
HAS Reservoir Temperature Sensor (Thermistor) Mounting
Upper Manifold Assembly
6-32 tapped hole
for Ringlet
Mounting. Screw
included.
Temperature Sensor
Attach Sensor
Cable to Tie Rod
with Zip Tie
Reservoir Temperature: HAS500 manifolds are equipped with mounting provisions to
accept a thermistor. HAS 500 Series drive kits include the thermistor, 5 meter cable and
macro in the drive to warn of High Oil Temp with the option to enable shut down HAS
operation on over temperature conditions.
PPaarrkkeerr HHaannnniiffiinn CCoorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
48
wwwwww..ppaarrkkeerr..ccoomm/
cylinder
HAS Reservoir Temp Sensor Installation