((AAddjjuussttaabbllee  ssppeeeedd  eelleeccttrriiccaall  ppoowweerr  ddrriivvee  ssyysstteemmss))  aanndd  
((FFuunnccttiioonnaall  ssaaffeettyy  ooff  eelleeccttrriiccaall//eelleeccttrroonniicc//pprrooggrraammmmaabbllee  eelleeccttrroonniicc  ssaaffeettyy--rreellaatteedd  ssyysstteemmss))  
STO aligns to the following aspects of this standard: 
• Safety Integrity Level 3
Probability of dangerous random hardware failures per hour (PFH) must be ≤ 10
-7 
Subsystems type A according to EN61508-2:2001 para 7.4.3.1.2 
Hardware Fault Tolerance (HFT) = 1 
Safe Failure Fraction (SFF) must be ≥ 90% 
  
As assessed to EN ISO13849-1 and EN61800-5-2 and certified by BGIA (a German 
trade association for industrial safety) the 890 frames B to F have the following 
related safety values:- 
Criterion  Requirement 
Value achieved 
SIL3 
For type A subsystems, HFT = 1: 
SFF ≥ 60% 
98% 
SIL3 
10
-7
 ≥ PFH ≥ 10
-8
1 x 10-9
PLe 
Category 3; PFH ≤ 4,29 x 10
-8
1 x 10-9
PLe 
30 years ≤ MTTFd < 100 years 
100 years
1
PLe 
DC = medium 
Medium 
Mission Time  20 years 
20 years 
Note: all values quoted in this table are valid only when the two STO user inputs are driven 
independently. This is as required by EN ISO 13849-1 category 3. See the Alignment to European 
Standards section in this chapter for the required architecture which must be used throughout the 
machine design relevant to the drive under consideration. 
In addition to the mandatory requirements of EN61800, the STO functionality has been 
subjected to testing for immunity at higher levels. In particular it has been tested for radiated 
immunity up to 3GHz which includes frequencies used by mobile telephones and walkie-talkies. 
1
 EN ISO13849 limits MTTFd to 100 years.